What are the sample requirements? How shall samples be stored after sample collection? How fresh or old can samples be?
Please
note: For any MolYsis™-based kits the microbial cells need to be intact!
After
taking the samples, please cool the samples in the fridge at ~8°C for short-term
storage.
Optimally, fresh samples are used for SepsiTest™-UMD and Micro-Dx™ for
the highest detection sensitivity.
The recommendation is to process samples
within 48 hours after collection.
If longer storage is necessary:
If longer storage is necessary, please protect the microbes with sterile glycerol
(approximately 20% of the sample) before freezing at preferably -80°C.
Please
refer to UMD-Tubes*, if you would like to have already
prepared sample tubes.
Make sure that the sample and glycerol are properly
mixed in both cases.
Don’t freeze samples unprotected, as microorganisms can
get lysed by the freeze-thaw cycle!
Storage
solutions
Storage solutions protecting the DNA/RNA need to be evaluated carefully because some of them
already initialize cell lysis.
For example, DNA/RNA Shield (Zymo Research, USA)
cannot be used for samples that shall be used in any MolYsis™-based kits.
* UMD-Tubes from Molzym are sold separately as Research Use Only (RuO) consumables.
Related Articles
What are the sample requirements? How shall samples be stored after sample collection? How fresh or old can samples be?
Please note: For any MolYsis™-based kits the microbial cells need to be intact! After taking the samples, please cool the samples in the fridge at ~8°C for short-term storage. Optimally, fresh samples are used for the highest detection sensitivity. ...
Which sample sizes can be used?
Clinical Sample Size & Volume For SepsiTest™-UMD and Micro-Dx™: Fluid samples: 1 ml. We recommend using as much sample volume as possible. For samples with smaller volumes, a buffer for volume adjustment to 1 ml is included in the kits. Tissue ...
Which samples can be used for SepsiTest™-UMD?
SepsiTest-UMD & Clinical samples For SepsiTest™-UMD the following clinical samples are applicable: Body fluids: e.g., ascites, broncho-alveolar lavage, whole blood (EDTA- or citrate-stabilized), CSF, pleural fluid, pus, synovial fluid Tissues: e.g., ...
Which samples can be used for Micro-Dx™?
Micro-Dx & Clinical sample For Micro-Dx™ the following clinical samples are applicable: Body fluids: e.g., whole blood (EDTA- or citrate-stabilized), pleural fluid, cerebrospinal fluid, ascites aspirates, broncho-alveolar lavage, blood cultures, ...
Can the SelectNA™plus instrument process any number of samples?
Yes, the SelectNA™plus instrument can process any number of samples between 1 and 12. The sample number must be selected while loading the instrument for each run.